DTM Series Blackbody Calibration Source(Radiation Source)

DTR-50NG Blackbody Radiation Source

◇ Introduction ◇ Function◇ Parameter◇ Product order◇ Download◇ Related products


DTM Series blackbody calibration source(radiation source) adopts a black body body and an integrated temperature control structure, and the working temperature range is 30℃~50℃. It can optionally communicate with a computer through RS232. High emissivity, good stability, small uncertainty and easy operation.

DTM Series blackbody radiation source the main function is to generate standard radiation at a certain temperature, so it is mainly used to verify various radiation thermometers in temperature measurement, such as optical high humidity meter, infrared thermometer, infrared thermal imager Etc., 

Our company's DTM blackbody calibration source are divided into two types: cavity and surface source. The temperature range covers low, medium and high temperature sections. Customers can choose two different electrical control methods: ordinary type and color touch screen according to their needs.

Technical indicators

Production nameLow temperature blackbody calibration sourceLow temperature blackbody calibration sourceMedium temperature blackbody calibration source
ModelDTM-50NGDTM-30NGDTM-550G
Temperature range-50℃~80℃,-30℃~80℃,50℃~550℃,
EmissivityΕ> 0.995Ε> 0.995Ε> 0.995
Cavity sizeΦ65 mmΦ65 mmΦ65 mm
Stability of temperature control≤0.1%t/10min, (the greater of 0.1℃ and 0.1%t)/10min≤0.1%t/10min, (the greater of 0.1℃ and 0.1%t)/10min≤0.1%t/10min, (the greater of 0.1℃ and 0.1%t)/10min
Power supply220VAC 50Hz220VAC 50Hz220VAC 50Hz
Power3KW3KW3KW
Target surface uniformity≤ (the greater of 0.15℃ and 0.15%)≤ (the greater of 0.15℃ and 0.15%)≤ (the greater of 0.15℃ and 0.15%)
temperature resolution0.1℃0.1℃0.1℃
Overall dimensions300*215*280 mm300*215*280 mm240*375*290 mm
Net weightabout 6Kgabout 6Kgabout 6.5Kg


Production nameMedium temperature blackbody calibration sourceHigh temperature blackbody calibration sourceHigh temperature blackbody calibration source
ModelDTM-700GDTM-1200GDTM-1500G
Temperature range50℃~700℃,100℃~1200℃,500℃~1500℃,
EmissivityΕ> 0.995Ε> 0.995Ε> 0.995
Cavity sizeΦ65 mmΦ50 mmΦ50 mm
Stability of temperature control≤0.1%t/10min, (the greater of 0.1℃ and 0.1%t)/10min≤0.1%t/10min, (the greater of 0.1℃ and 0.1%t)/10min≤0.1%t/10min, (the greater of 0.1℃ and 0.1%t)/10min
Power supply220VAC 50Hz220VAC 50Hz220VAC 50Hz
Power1.2KW2.0KW5.5KW
Target surface uniformity≤ (the greater of 0.15℃ and 0.15%)≤ (the greater of 0.15℃ and 0.15%)≤ (the greater of 0.15℃ and 0.15%)
temperature resolution0.1℃0.1℃0.1℃
Overall dimensions300*450*370 mm300*530*370 mm500*720*900 mm
Net weightabout 15Kgabout 20Kgabout 120Kg
Production nameHigh temperature blackbody calibration sourceUltra high temperature blackbody calibration source
ModelDTM-1600GDTM-2500G
Temperature range500℃~1500℃,800℃~2500℃, 800℃~3000℃(vacuum)
EmissivityΕ> 0.995Ε> 0.995
Cavity sizeΦ50 mmΦ50 mm(Φ25 mm 3000℃)
Stability of temperature control≤0.1%t/10min, (the greater of 0.1℃ and 0.1%t)/10min≤0.15℃ of working temperature t℃/10 min
Power supply220VAC 50HzThree-phase 380V 50Hz
Power5.5KW50KW
Target surface uniformity≤ (the greater of 0.15℃ and 0.15%)≤0.15℃ of working temperature t℃
temperature resolution0.1℃0.1℃
Overall dimensions500*720*900 mm

Furnace: 1150*500*1300 mm

Transformer: 650*570*745 mm

Humidity control device: 600*600*1420 mm

Net weightabout 120Kgabout 500Kg


Dual Cavity Black body Radiation Source

DTM Series Blackbody Calibration Source(Radiation Source)
  • Online message

  • Your name
    Your title must be filled
  • Cellphone number
    Mobile phone number is required
  • whatsapp/wechat
    Optional
  • Type of consultation
    Required, please select the type of consultation
  • Consultation content
    Required, what is the content you want to consult?
  • Verification code: Please fill in the calculation result.
This article is read 9254 Times
Previous:DT-ECT Micro Dry Well Furnace Temperature Calibratorsnext:DTZ-TS Temperature switch automatic calibration system

Contact us

DEARTO QR codeHeadquarter Address Tai'an High-tech Development Zone,  Shandong Province 
Telephon :+86 0538-5089056 +86 13605384645  +86 13953856217 
Fax : +86 0538-5059718 
After sale:+86 0538-5050959 +86 13605384645 
Website : m.auto-surfer.com 
E-mail : tadt17@dearto.cn /  tadtzdh@dearto.cn

Copyright? Tai'an Detu Automation Instrument Co., Ltd.             Lu ICP 14024757-1           Business license inquiry

国产--精品一区二区三区| 国产人妻777人伦精品hd| 无码AV人妻一区二区三区四区 | 免费无码毛片一区二区app| 销魂美女图库| 娇妻穿丁字裤公交车被c| 18禁喷水流白浆自慰视噜噜噜| 台湾三级| 午夜欧美精品久久久久久久 | zoom与牛性胶zoom| 掀开奶罩边躁狠狠躁软学生电影| 国产AV无码| 换着玩人妻hd中文字幕| yin荡到骨子里的sao货| 国产精品久久久久久无码不卡| 色偷偷WWW.8888在线观看 | 特发性震颤是什么病| 亚洲和欧洲一码二码区别在| 久久精品国产亚洲av无码偷窥| jizzjizz欧美69巨大| 东北50岁熟妇露脸在线| 顶级私人家庭影院| 日日麻批免费40分钟无码 | 国产97人人人超碰超爽| 337P日本欧洲亚洲大胆张筱雨| 中国极品少妇xxxxx| 他底下好硬蹭着我想要| 性饥渴的老妇教我玩她| 一对浑圆的胸乳被揉捏动态图| 双性娇喘浑圆奶水h男男| 少洁白妇无删减全文阅读| 交换俱乐部娇妻奶呻吟啊视频| 日本人是sb吗| 99蜜桃在线观看免费视频网站| 久久免费人成网站福利院| 成人无码一区二区三区| 我和子的与子乱视频| 丁香花在线影院观看在线播放| 99这里只有精品| 最近韩国日本免费观看MV| 永久免费观看不收费的软件app|